Portable Digital Auto 4 Vials Reactor

1.Structure is compact, the reactor can react 4 samples at the same time. 2.The reactor using sealed with micro-return line for reacting without condensed water. 3.The reactor can set the heating temperature between 20-180℃,and contains a thermal fuse that prevents overheating. 4.The reactor can set the heating period between 0-120mins, and turning off the heating element automatically with warning beep. 5.The reactor equips transparent plastic protection shield to protect the operator, and each tube is subjected by pressuring and heating test.
Chat Now

Product Details


portable digital auto 4 vials reactor

portable digital auto 4 vials reactor

TECHNICAL DATA 

Temperature Range

20-180℃

Accuracy

±3°C (@ 25°C)

Capacity

4 vials

Warm-up Time

10 - 15 minutes, depending on selected

 

temperature

Heating period

0-120mins

Environment temperature

(0~40)℃

Environment relative humidity

<=85%

Power Supply

DC 12V/10A

Dimensions

110×170×135 mm


portable digital auto 4 vials reactor

Start heating

Press “Start”button to trigger heating process. The reactor will beep once the setting temperature is reached. Then, put the test tube into heater block hole, the timer will start to count down the setting period. The “Balance time” shows on the screen. After the “Balance time” become “0”. A beep will be heard and the heating element will turn off. It means the heating process is finished.


portable digital auto 4 vials reactor

Thermostats are devices that directly or indirectly control one or more heat and cold sources to maintain the desired temperature. To achieve this function, the thermostat must have a sensitive component and a transducer that measures the change in temperature and produces the desired effect on the converter. The converter converts the action from the sensitive component into a function that can properly control the temperature changing device.


portable digital auto 4 vials reactor

COD: In environmental chemistry, the chemical oxygen demand (COD) is an indicative measure of the amount of oxygen that can be consumed by reactions in a measured solution. It is commonly expressed in mass of oxygen consumed over volume of solution which in SI units is milligrams per liter (mg/L). A COD test can be used to easily quantify the amount of organics in water. 