Introduction:
New type waterproof water treatment instrument instrument satisfies the demand of most users with high rate between price and performance.There are three types:portable dissolved oxygen (DO) meter LH-D9,portable PH/ORP meter LH-P5,portable conductivity meter LH-C6 with classification of waterproof IP67 and shockproof design.It is suitable for the fields of monitoring under rugged environment and underwater works.
Portable DO meter can test the dissolved oxygen in water ,which is used in many fields like aquaculture ,water treatment ,environmenal monitoring ,river regulation and so on.
Parameter:
DO meter | |||
Mode | Saturation% | Oxygen (Mg/L) | Temperature |
Range | 0 to 199.9 | 0~19.99 | 0.0-50.0℃(32-122℉) |
resolution | 0.1 | 0.01 | 0.1℉(0.1℃) |
Accuracy | ±1.5% FS | ±1.5% FS | ±0.9℉(±0.5℃) |
Responding Time | 1min | 1min | 1min |
Calibration | At most 2 points | ||
Temperature Compensation | Auto (ATC) from 32-122℉ or 0-50℃ | ||
Operating Temperature | 32-122℉(0~50℃) | ||
Battery | 2*AA | ||
Probe | Plastic electrode |
Operation processess:
Calibration
1.Turn on the meter or return to the Measurement Mode.
2.Select % Mode and Immerse the DO probe in the zero-oxygen solution until READY shows.(Get high accuracy ,please immerse the probe for 3min or longer .The next steps must be performed only when the expectation value will be below 5%.)
3.Press MODE a few times until the Calibrating is flashing on the Second Display, press HOLD/SET to enter Calibration Mode. (Calibrating stop flashing)
4.The meter will automatically recognize the standard solution and automatic calibration. During this process, calibration value will be shown on the Second Display.
5.After Calibration, meter automatically returns to Measurement Mode.
100% Calibration
In the Measurement Mode
1.Turn on the meter or return to the Measurement Mode.
2.Select % Mode and Place the probe at 1cm above the liquid until READY shows.(Get high accuracy ,please keep the probe for 1min or longer .)
3.Press MODE a few times until the Calibrating is flashing on the Second Display, press HOLD/SET to enter Calibration Mode. (Calibrating stop flashing)
4.The meter will automatically recognize the standard solution and automatic calibration. During this process, calibration value will be shown on the Second Display.
5.After Calibration, meter automatically returns to Measurement Mode.
At most 2 points calibration: 0% and 100%, when the solution cannot be recognized, show “Err” for 2s. Then automatically returns to Measurement Mode.
NOTE: For 100% calibration, air calibration way is a simple, quick, approximate method.
(For high accuracy, we recommend that users should regularly calibrate. In the following situation, users must recalibrate meters.)
Replace probe
after measuring aggressive chemicals
Restore Factory Default
Press MODE six times, R flash on the Main Display,press HOLD/SET to
restore factory default and meter will return to Measurement Mode after LCD full-shown for 1S.
Auto power-off
The meter will automatically power off without any operation for 8 min.
Our company:
Our service:
Certifications:
FAQ:
1. Q: Are you trading company or manufacturer ?
A: We are factory.
2. Q: How long is your delivery time?
A: Generally it is 5-10 days if the goods are in stock. or it is 15-20 days if the goods are not in stock, it is according to quantity.
3. Q:Why choose Lohand ?
A:We are leading manufacture,OEM&ODM service are offered.
4. Q:How about the sample of Lohand product?
A:We could send you the samples but the freight and the sample are charged.
5. Q:How about Lohand delivery time?
A:Shipped in 3 days after payment.